Calibration of Arm Encoder (Near Slip ring) of Regioman Press



  1. Switch Off power
  2. Remove Encoder and connect new Encoder
  3. Switch ON power
  4. Bring Arm-1 in front position (Always take Arm-1 in front side every time when we replacing or calibrating sleepering encoder)
  5. Place level bottle on Arm-2 side
  6. Make proper levelling
  7. Go to Setting Menu on the touch screen
  8. Select Calibrate Option(password 102) and press enter
  9. Select Steps angle encoder option
  10. Press Start
  11. After pressing start button the value of Steps angle encoder option changes to zero and this is the zero position of sleepering encoder