CG Drive Trip Errors, Causes and Remedies

Sr. No.
Error
Means
Causes
1
UV
DC bus under voltage
Low AC supply voltage
Low DC bus voltage when supplied by an external DC power supply
2
OV
DC bus over voltage
Deceleration rate set too fast for the inertia of the machine
Mechanical load driving the motor
3
OI.AC**
Drive output instantaneous over current
Insufficient ramp times
Phase to phase or phase to ground short circuit on the drives output
Drive requires autotuning to the motor
Motor or motor connections changed, re-autotune drive to motor
4
OI.br**
Braking resistor instantaneous over current
Excessive braking current in braking resistor
Braking resistor value too small
5
O.SPd
Over speed

Excessive motor speed (typically caused by mechanical load driving the motor)
6
tunE
Auto tune stopped before
completion
Run command removed before autotune complete
7
It.br
I2t on braking resistor
Excessive braking resistor energy
8
It.AC
I2t on drive output current
Excessive mechanical load
High impedance phase to phase or phase to ground short  circuit at drive output
Drive requires re-autotuning to motor
9
O.ht1
IGBT over heat based on drives  thermal model
Overheat software thermal model
10
O.ht2
Over heat based on drives heatsink
Heatsink temperature exceeds allowable maximum
11
th
Motor thermistor trip
Excessive motor temperature
12
O.Ld1*
User +24V or digital output overload
Excessive load or short circuit on +24V output
13
O.ht3
Drive over-heat based on thermal model
Overheat software thermal model
14
O.ht4
Power module rectifier over  temperature
Power module rectifier temperature exceeds allowable maximum
15
cL1
Analog input 1 current mode, current loss
Input current less than 3mA when 4-20 or 20-4mA modes selected
16
SCL
Serial communications loss time-out
Loss of communication when drive is under remote control
17
EEF
Internal drive EEPROM trip
Possible loss of parameter values

18
PH
Input phase imbalance or input phase loss
One of the input phases has become disconnected from the drive (applies to 200/400V three phase drives only, not dual rated drives)
19
rS
Failure to measure motors stator resistance
Motor too small for drive
Motor cable disconnected during measurement
20
CL.bt
Trip initiated from the control word
Control word has initiated a trip
21
C.Err
SmartStick data error
Bad connection or memory corrupt within SmartStick
22
C.dAt
SmartStick data does not exist
New/empty SmartStick being read
23
C.Acc
SmartStick read/write fail
Bad connection or faulty SmartStick
24
C.rtg
SmartStick/drive rating change
Already programmed SmartStick read by a drive of a different rating
25
O.cL
Overload on current loop input
Input current exceeds 25mA
26
HFxx
trip
Hardware faults
Internal drive hardware fault (see the Advanced User Guide)

Sr. No.
Error
Means
Remedy
27
OVL.d
I x t overload (I = current, t = time)
Reduce motor current (Load)
28
hot
Heatsink/IGBT temperature high
Reduce ambient temperature or reduce motor current
29
br.rS
Braking resistor overload
See Menu 10 in the Advanced User Guide
30
AC.Lt
Drive is in current limit
See Menu 10 in the Advanced User Guide
31
FAIL
Failed attempt to read stick
An attempt has been made to read the stick when the drive was not disabled or tripped, or the stick is read-only