Encoder Calibration for Folder Baumuller Motor of Regioman Press


Setting of zero position of Folder
1. Remove the knife where it is mentioned as “0” position
2. Fix the gauge
3. Unload the job
4. Press one safe stop near the knife
5. Close all the covers
6. Remove all other stops
7. Connect the calibration panel
8. Select switch 1
9. Remove the safe stop button
10. No green light means no safe stop
11. Press black push button
12. Press the triangle button one time for zero setting. It starts flashing
13. Remove the gauge
14. Release the black push button. Green light should be off
15. Press the triangle button one time
16. Press the triangle button one more time
17. Calibration is completed
18. Fix the knife with 80 N force tool
19. Switch of the selector switch and remove the calibration panel
• If encoder of folder motor (Master) is changed, we have to first latch the encoder with motor by performing latching procedure. Then make zero calibration of folder.
• If encoder of folder motor (slave) is changed, we have to first latch the encoder with motor by performing latching procedure. No need to make folder zero calibration.
• If the folder encoder is changed the zero calibration of folder is required.