Updated Reelstand Lenze Core Drive Programming of Regioman Press

Downlaod:-From Card to Drive

  1. Switch Off power
  2. Take out interbus module and connect lenze card module
  3. Switch ON power
  4. It shows 0 at the start
  5. Yellow and Green LED glows-it means parameter set matches for that Drive
  6. To start download program from card to drive-push T1 button until 9 display (hold for 3 seconds)
  7. Display starts counting from 9 to 0
  8. Display show 0 means procedure finished.
  9. Check in software version on HMI. It should be as follows:
Core 1 – 135.5
Core 2 – 135.5
In feed – 121
Arm -      311


Upload:-From Drive to Card

1.  Switch Off power
2.  Take out interbus module, Remove write protection of the card and             connect lenze   card module.
3.  Switch ON power
4.  It shows 0 at the start
5.  Select Empty data set by pressing T3 button on the card module,( here        4-9 are empty data sets, so select any one of them.)

    • 4- for Core Drive 1
    • 5- for Core Drive 2
    • 6-for Infeed Drive
6.  To start upload program from drive to card-push T2 and hold for 3               seconds
7.   LED starts blinking- it means upload starts
8.    After some time LED is idle-it means upload finished
9.    Switch Off power and take out Lenze card module and connect interbus          module

10.  Switch ON power

Calibration of Arm Encoder (Near Slip ring) of Regioman Press



  1. Switch Off power
  2. Remove Encoder and connect new Encoder
  3. Switch ON power
  4. Bring Arm-1 in front position (Always take Arm-1 in front side every time when we replacing or calibrating sleepering encoder)
  5. Place level bottle on Arm-2 side
  6. Make proper levelling
  7. Go to Setting Menu on the touch screen
  8. Select Calibrate Option(password 102) and press enter
  9. Select Steps angle encoder option
  10. Press Start
  11. After pressing start button the value of Steps angle encoder option changes to zero and this is the zero position of sleepering encoder