Baumuller Error No. 4

Link module error, duplicate or wrong ID

A duplicate or wrongly assigned Parameter ID was detected on starting the controller software program. This error is used for diagnosis during software development. The error does not occur during operation.
The controller software is not started correctly. The drive controller cannot be released. No acknowledgement possible.

Source and Remedy 
The controller software was wrongly generated or saved. Replace the controller software.

MICE Settings on control desk of Regioman Press

 Management network Mice switch , following IP address has to be given to the laptop .


Open internet explorer or Mozilla firefox  and input the IP address 10.35.156.3 for that particular Mice switch LS1….LS2….LS3….LS4….LS5 ……..etc .


Login ID : admin , Password : private , Language : English


Configuration page will be Open .


Open diagnostic and Open signal contact


Open signal contact


Open Manual settings


Select closed button on manual settings


Press set button on signal contact 1


Repeat the procedure from 6 to 9 for signal contact 2



Open load/save option and select save button 



Baumuller Error No. 502

Communication has failed between the primary control and SDC or MDS

The SDC or MDS does not receive any data from the primary control. As the corresponding VL is no longer operated this VL is braked with secure hold

Source and  Remedy 
Sercos ring for primary control has failed. 
Identifier: Fallen or severed optical fibre
Reinstate optical fibre link 
Ethernet communication with primary control has failed. 
Identifier: The green LED on connector X39 (ETH0) is off or the Link LED on the switch is off.
Check the Ethernet connector on the M drive and at the switch and or replace the Ethernet cable. 
ETHERNET connection with control: The ETHERNET switches run in half-duplex operation. This can lead to increased collisions. Automatic configuration of the switches can cause this case. 
Identifier: Ethernet switch is configured for half-duplex
Manual setting to full duplex operation. 
ETHERNET connection with control: The MAC addresses in the system are not clear. This causes the telegrams to be incorrectly routed, which means loss of telegrams for individual subscribers. [From MDS with the serial number 0114 xxxx the MAX is configured in the serial EEPROM of the controller cassettes by the manufacturer. Problems can occur if several flash cards on an MDS configured in this way are pre-recoded and saved with parameters and are then slotted into an unconfigured MDS.] Check the parameters ID1461 and ID1462. Written together as 6 byte value, each address may only occur once in the ETHERNET.
Replace the controller cassette
OR
Change over the parameterised values of the ID1462 
Primary control has failed: The sign-of-life monitoring with the primary control must toggle the handshake bit in the control word within a parameterizable time. 
Identifier: Failure of all functions carried out by this primary control.
Check primary control 
Sign-of-life monitoring with primary control is incorrectly (too small) parameterised. 
Identifier: The parameter 1010 CommTimeout (for MDS) or SIS timeout (for SDC) is incorrectly parameterised.
Set parameter 1010 to correct value.

How to fill the scholarship form for 2014-2015

Open following site 
https://escholarship2014-15.maharashtra.gov.in/Account/Login/Login.aspx

Bellow Window Open



Click on
For New Registration And Application Of 2014-2015 Click Here

Bellow Window Open and create a New Account by filling required feild.


Click on Create User, then bellow Window open

Click on Update Profile, then bellow Window open.



Fill the above form and save it, Take a print out from following window.



Click on Print Application Form to take a print out or save in Computer.

Baumuller Error No. 1000

USS - communication with axis not possible

The diagnostic system cyclically scanns the error storage of the individual drives. If the communication to one of the drives cannot be set up, this is signalled via the error number 1000.
No effect on machine control Only display at diagnostic system

Source and Remedy 
Error only at one controller:
Incorrect controller parameterisation Check controller parameter set:
USS Basic address (ID 329)
USS No. of Axles (ID 316) )

Error only at one controller:
Cable connection interrupted Check connection cable 
Connected connector on controller side (X23A and X23B) 
Connector connected on SDC side (X5) 
Connector connected to conversion module 

Error only at one controller: Wrong configuration in the diagnosis system Check configuration data (BAS) 
Error at several controllers: Cable connection interrupted Check the complete cable branch. The error lies between the last controller whose communications are running and the first controller with interrupted communication 
Error at several controllers: Wrong port address at diagnosis system Check configuration data (BAS)