- Load the Product.
- Web up the paper.
- Make zero at Console.
- Connect Laptop to machine.
- Open putty.
- Connect to PU whose BW has to be calibrated.
- Type REGI, press enter
- Type E (Element), press enter.
- Type C (Calibrate), press enter.
- Type BW
- Type 3 or 4 (3 for operating side BW and 4 for gear side BW)
- Measure voltage at 2 and 4 for BW 3,
6 and 8 for BW 4 of A621 MCU module.
Keep meter connected for monitoring of values.
- Type H
- Meter reading starts to decrease.
- Press B when meter shows 0.30 Volt for minimum setting (Standard-0.20 Volt).
- Meter reading starts to increase.
- Press E when meter shows 9.3 Volt for maximum setting (Standard –9.80 Volt).
- Meter reading starts to decrease and stops at center i.e. 5.7 Volt or 5.8 Volt.
- Type Q for quit.
- Do the mechanical ZERO setting.