Calibration of Ink Box of Regioman Press

  1. Connect Service Laptop to RS 20 Switch (port no. 8)
  2. Open Hyper terminal window by entering correct IP address of Print Unit (Unit Controller) Start – Accessories, - Communications – Hyper Terminal
  3. Hyper terminal window shows Telnet session – Using TCP - IP
  4. Press Enter
  5. Hyper terminal window shows <Hindustan Times_DE1>
  6. OR
    1. Open Putty
    2. Select the Particular Unit which want to Calibrate
    3. Press Enter
    4. Putty window shows <Hindustan Times_DE1>
  7. Type TFA to calibrate ink box i.e. <Hindustan Times_DE1> TFA
  8. Press Enter
  9. Press C for Calibration and press Enter
  10. Window shows DW-NR? (it means select couple number which we want to calibrate, for example if we want to calibrate ink box for couple number 4 then follow next step)
  11. DW-NR? 4
  12. Press Enter (Calibration Starts)
  13. Window shows Calibration Running
  14. After some time OK message displayed
  15. Press C to calibrate another ink box or Q to Quit telnet session
  16. After Ink Box Calibration finished, we need to replace FA_WE_DU.CFG file in our data base.
  17. Upload program from UC-100 flash card to our service Laptop and replace the above file in our database for that particular Unit.
  18. FA_WE_DU.CFG file name is same for all units but the values inside may be different so save this files separately for each unit.