Calibration of Folder DIA Cylinder of Regioman Press


Calibration of Folder DIA Cylinder:  UNLOAD THE PRODUCT

  1. After completion of the mechanical work keep the potentiometer out of the machine and check following:

    1. Rotate the potentiometer to minimum position (0 volts) and at this position check if the motor can be further rotated to minus side (It should not be possible). Now rotate the pot to maximum position (14.2 volts) and check if the motor can be rotated further to plus position (It should not be possible). 

  1. Now ask mechanical persons to set the minimum position of the cylinder to be -2.5 mm on the dial gauge.

  1. Set the potentiometer to 1.14 volts and note the hex value (for minimum) on the lap top as follows:
    1. Connect the lap top to putty
    2. Connect to Folder UC
c.    Type
   MONI <ENTER>
d c0511014 <ENTER> for front folder and  d c0521014 <ENTER> for back folder
    1. Note down the hex value

  1. Fix the potentiometer in same position

  1. Ask the mechanical persons to rotate the motor to plus direction and set the maximum position of cylinder to be + 2.5 mm on the dial. The potentiometer should read 13.06 volts

  1. Note the hex value on lap top (for maximum) as per step 3.

  1. Close putty

FOR FIX THE MINIMUM AND MAXIMUM VALUE


  1. Again connect to putty and enter as follow:

    1. Connect to Folder UC
b.    Type
      EICHWERT DM1 ’1a 281 e3D’ <ENTER> for front folder
   
       EICHWERT DM2 ’1a 281 e3D’ <ENTER> for back folder

   281 :  In place of 281 enter the noted minimum hex value

   e3D :  In place of e3D enter the noted maximum hex value


.
FOR CHECK THE ENTER VALUES OF MINIMUM AND MAXIMUM

9.    Check for the entered value as follows:

a.    Connect to putty
b.    Connect to Folder UC
c.    Type:
EICH DM1 for front folder
EICH DM2 for back folder

The entered values are shown

10.Cold start the UC 4 of folder

11. Check the Motor for minimum and maximum position. Also check if the motor
moves further to minus at minimum (It should not be possible) and if it moves  further to plus at maximum (It should not be possible). Check the potentiometer  voltages at both positions. 



Telnet session

<Hindustan_Times_FER1>MONI

ROOT: restarting 'MONI' (#280000), data at $1c12000
FILE: Error in de_cntrl TCGETS: $102
OK >d c0511014
C0511014  07 80 07 84 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0511024  00 00 00 00 08 00 01 FA   08 00 01 FC 00 00 00 00   ........ ........
C0511034  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0511044  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0511054  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0511064  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0511074  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0511084  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0511094  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C05110A4  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C05110B4  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C05110C4  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C05110D4  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C05110E4  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C05110F4  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0511104  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0511114  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0511124  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0511134  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0511144  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........

OK >d c0521014
C0521014  08 89 07 92 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0521024  00 00 00 00 08 00 02 01   08 00 02 00 00 00 00 00   ........ ........
C0521034  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0521044  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0521054  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0521064  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0521074  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0521084  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0521094  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C05210A4  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C05210B4  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C05210C4  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C05210D4  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C05210E4  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C05210F4  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0521104  00 00 00 00 00 00 00 00   00 00 00 00 50 00 13 EE   ........ ....P...
C0521114  50 FD D5 F0 00 00 00 00   00 00 00 00 00 00 00 00   P....... ........
C0521124  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0521134  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
C0521144  00 00 00 00 00 00 00 00   00 00 00 00 00 00 00 00   ........ ........
OK >



Telnet session


<Hindustan_Times_FER1>EICHWERT DM2 '1a 145 e3B'

ROOT: restarting 'EICH' (#1f0000), data at $1c2a000
(55 73 1 2): 0000,001a 0000016a 00000e3e

<Hindustan_Times_FER1>EICH DM2

ROOT: restarting 'EICH' (#1f0000), data at $1c2a000
(55 73 1 2): 0000,001a 00000145 00000e3b