MCU-3 Motor Control Unit

Brief Description
• INTERBUS local-bus station
• Diagnosis LEDs
• 8 digital outputs 24 V / 0.5 A, electrical isolation from INTERBUS
• Status LEDs for all outputs
• 4 analog inputs, 12 bit, connection of potentiometers
• ID code: 127 dez / 7F hex
• Number of data words: 4




The following diagnosis LEDs serve to indicate the operating state of the INTERBUS at start-up and error
diagnosis:
UL
UL LED green
Monitoring the +5 V supply voltage

CC
Cable Check LED green
Monitoring the remote-bus input cable:
The LED is lit if the cable connection is O.K. and the INTERBUS master not
resetting. In the case of an INTERBUS or power-up reset the LED is inactive.

BA
Bus Active LED green
Indicates cyclic data transmission accross the INTERBUS signal lines.

E
Error LED red
Monitoring the micro-controller: The LED indicates that the micro-controller does not operate duly.

MCU-5 Motor Control Unit

Brief Description
The subassembly provides two mutually independent full bridge control systems for the operation of two
24V-DC motors with a rated current up to 10 A per motor. The motors can be actuated in the pulse-width modulated mode or in continuous operation.




The following diagnosis LEDs serve to indicate the operating state of the INTERBUS at start-up and error
diagnosis:
UL
UL LED green
Monitoring the +5 V supply voltage

CC
Cable Check LED green
Monitoring the remote-bus input cable:
The LED is lit if the cable connection is O.K. and the INTERBUS master not
resetting. In the case of an INTERBUS or power-up reset the LED is inactive.

BA
Bus Active LED green
Indicates cyclic data transmission accross the INTERBUS signal lines.

E
Error LED red
Monitoring the micro-controller: The LED indicates that the micro-controller does not operate duly.

MCU-7 Motor Control Unit

Brief Description
• INTERBUS local bus node
• Diagnostics LEDs
• Outputs for 8 synchronous motors 24 V / 2.4 W, electrical isolation from INTERBUS
• Phase-shifting capacitors included
• Status LEDs for all outputs
• 8 analog inputs, 12 bit, only for connecting potentiometers
• ID code: 127 dec / 7F hex

• Number of data words: 8




The following diagnosis LEDs serve to indicate the operating state of the INTERBUS at start-up and error
diagnosis:
UL
UL LED green
Monitoring the +5 V supply voltage

CC
Cable Check LED green
Monitoring the remote-bus input cable:
The LED is lit if the cable connection is O.K. and the INTERBUS master not
resetting. In the case of an INTERBUS or power-up reset the LED is inactive.

BA
Bus Active LED green
Indicates cyclic data transmission accross the INTERBUS signal lines.

E
Error LED red
Monitoring the micro-controller: The LED indicates that the micro-controller does not operate duly.

MCU-2 Motor Control Unit

Brief Description
• INTERBUS local-bus station
• Diagnosis LEDs
• Outputs for 4 synchronous motors 24 V / 25 W, electrical isolation from
INTERBUS
• Power-factor correction capacitors not included
• Status LEDs for all outputs
• 4 analog inputs, 12 bit, connection of potentiometers
• ID code: 127 dez / 7F hex

• Number of data words: 4




The following diagnosis LEDs serve to indicate the operating state of the INTERBUS at start-up and error
diagnosis:
UL
UL LED green
Monitoring the +5 V supply voltage

CC
Cable Check LED green
Monitoring the remote-bus input cable:
The LED is lit if the cable connection is O.K. and the INTERBUS master not
resetting. In the case of an INTERBUS or power-up reset the LED is inactive.

BA
Bus Active LED green
Indicates cyclic data transmission accross the INTERBUS signal lines.

E
Error LED red
Monitoring the micro-controller: The LED indicates that the micro-controller does not operate duly.

MCU-1 Motor Control Unit

Brief Description

• INTERBUS local-bus station
• Diagnosis LEDs
• Outputs for 4 synchronous motors 24 V / 5 W, electrical isolation from      INTERBUS
• Equipped with power-factor correction capacitors
• Status LEDs for all outputs
• 4 analog inputs, 12 bit, connection of potentiometers
• ID code: 127 dez / 7F hex

• Number of data words: 4


The following diagnosis LEDs serve to indicate the operating state of the INTERBUS at start-up and error
diagnosis:
UL
UL LED green
Monitoring the +5 V supply voltage

CC
Cable Check LED green
Monitoring the remote-bus input cable:
The LED is lit if the cable connection is O.K. and the INTERBUS master not
resetting. In the case of an INTERBUS or power-up reset the LED is inactive.

BA
Bus Active LED green
Indicates cyclic data transmission accross the INTERBUS signal lines.

E
Error LED red
Monitoring the micro-controller: The LED indicates that the micro-controller does not operate duly.

How to fill the scholarship form of 7th standard for 2014

First visit the given bellow site
http://www.mscepune.in/gcc/FrmHssOnline.aspx
Bellow form open, filled it and click on submit




After submitting following format appear, Take a print out of bellow form.



I2t protection

The I2t protection keeps track of the motor temperature by monitoring the motor current and computing the over-temperature. Any current above the nominal value will produce a bigger or a smaller, but nevertheless an overheat to the motor, and on the same basis, a current below the nominal value will allow the motor to decrease its temperature for exmaple : down to the ambient temperature in the best case = current zero = motor stopped. While the motor has a current bigger than the nominal current the drive will consider that the motor temperature is increasing and when a certain threshold is reached the protection is triggered.

How to program the stacker PLC ( B&R) from laptop

1. Connect Laptop to B&R PLC at RS port.

2. Open Program as below.

3. D:\Muller Martini\_MM-Software 2009\PST\Revised PST 08052009\PW 4307.7653.4 (2009-05-06)_CD

4. Following windon appears


5. Dobble Click on

6. Following window appears


 7. Click on

 8. Click on Yes to Start programming.


 9. After 76 steps programming has complete.