Updated Reelstand Lenze In feed Drive Programming of Regioman Press

Download:-From Card to Drive

  1. Switch Off power
  2. Take out interbus module and connect lenze card module
  3. Switch ON power
  4. It shows 0 at the start
  5. Select number for particular drive by pressing T3 button on the card module

    • 3-Infeed Drive

6. Yellow and Green LED glows-it means parameter set matches for that Drive
7. To start download program from card to drive-push T1 button and hold for 3 seconds
8.  Display starts counting from 9 to 0
9.   Push T1 again
10. LED starts blinking- it means download starts
11. After some time LED is idle-it means download finished
12. Switch Off power and take out Lenze card module and connect interbus module
13. Switch ON power
14. Check in software version on HMI. It should be as follows:

Core 1 – 135.5
Core 2 – 135.5
In feed – 121
Arm -      311



Upload:-From Drive to Card

1. Switch Off power
2. Take out interbus module, Remove write protection of the card and             connect lenze card module.
3. Switch ON power
4. It shows 0 at the start
5. Select Empty data set by pressing T3 button on the card module,( here       4-9 are empty data sets, so select any one of them.)

    • 4- for Core Drive 1
    • 5- for Core Drive 2
    • 6-for Infeed Drive
6. To start upload program from drive to card-push T2 and hold for 3               seconds
7. LED starts blinking- it means upload starts
8.  After some time LED is idle-it means upload finished
9.  Switch Off power and take out Lenze card module and connect interbus           module

10. Switch ON power