1Switch OFF the supply power.
2Disconnect the module RTI 3 module.
3Connect the ROD-3 module.
4Connect the new DPO-1 card and check the jumper position must be on WRE.
5Connect the cable to laptop and new DPO module.
6Switch ON the supply power.
7Open the Hyper terminal.
8New connection window open. Type the name and select the COM1.
9Setting of connection window open.
10Follow procedure of A of page 2.
11Press Reset button onthe new DPO-1 module.
12Display B of page 3.
13Give the speed 0 5 (5000) on the ROD-3 module by toggle switch.
14Display C of page 3.
15Type MONI for selection of program DPO-1, it is necessary.
16Display D of page 3.
17SIGNAL-NUMBER : 00 display, then type the 00.
18SETTING OK? (Y/N) display, then type Y.
19END display.
20Press CTRL-E for display press speed.
21Display E of page 4.
22Press CTRL-R for reset counter.
23Display F of page 4.
24Press CTRL-D for clear reset-counter.
25Disconnect into Hyper terminal.
26Switch OFF the supply power.
27Remove the ROD-3 module.
28Connect the RTI 3 module.
29Switch ON the supply power.