EEPROM access error, wrong address
Access to the special parameter occurs if the value entered for parameter ID21 „DSV-Mode“ is 0 or 2.. The required address is selected via the parameter ID25 "EEPROM address" and the value read or written with ID26 "EEPROM Date". The M0 Offset is e.g. a special parameter in the emulated EEPROM
The error is signalled to the primary control. If the primary control switches the drive controller off, renewed release of the drive controller is prevented until the cause of the error is corrected and the error acknowledged.
The error can be acknowledged at the control centre after the cause of the error has been corrected.
Source and Remedy
Memory area for special parameter not found, wrong address Delete all parameters and special parameters on the flash card, load new data records and save. If this fails, replace flash card.