Pages


ll श्री गणेशाय नमः ll अनंत कोटि ब्रम्हांड नायक राजाधिराज योगिराज श्री सचिदानंद सद गुरु श्री संत गजानन महाराज की जय....

Google Custom Search


Baumuller Error No. 34

Positive maximum speed exceeded

This error message is triggered by the diagnosis module if the current motor speed ID487 "Speed Visu. [Ax]" exceeds the positive limit value entered in the Parameter ID46 "pos.max.speed[Ax]".
The rotary encoder used for monitoring the positive maximum speed is always the one used for the motor commutation. If the positive limit speed value is to be given for the load, a gear unit may possibly have to be taken into consideration, after acknowledging the error, the rotary encoder is reinitialised and if necessary the home position run is restarted.

The error is fatal and leads to immediate shutoff of the drive controller. In this case the drive coasts to a standstill. Renewed release of the drive by the controller is prevented until the cause of the error has been corrected and the error has been acknowledged.

Source and Remedy 
Incorrect parameterisation of the positive limit speed value or gearing factor between the motor and load incorrectly taken into account when parameterizing the positive limit speed value. Check the parameter ID46 "pos.max.speed.[Ax]". 
A malfunction in the motor commutation of synchronous motors can lead to malcommutation. The drive then possibly revs up to maximum speed after receiving the controller releases and shuts down with overspeed. 
Carry out new stop angle run and ensure that the drive can move freely throughout. Check the actual position recorded (rotary encoder ). 
Setpoint speed specified by the controls is too high. Check setpoint values! 
Recording of actual speed value faulty or wrongly parameterised. 
Check the parameter ID88 "pick-up PPR count [ax]", ID112 "Pick-up active [ax]". Replace rotary encoder.