Upload and Download Parameter of Lenze 8200 Vector

01 Press right arrow button

02 Press 1<->2 button             Display: 1 flashing

03 Press right arrow button               Display: USER 0001000 flashing

04 Press up arrow button                  Display: ALL 0002000 flashing

05 Press 1<->2 button             Display: 0 0001000 flashing

06 Press up arrow button                  Display: 0 0002000 flashing

07 Press right arrow button               Display: 0 flashing 0002000

08 For Upload:
    
Press 20times up arrow button    Display: 20 flashing 0002000
     
For Download:
     
Press 10times up arrow button    Display: 10 flashing 0001000

09 Press Enter button                         Display: for Upload: Save
                                                                          for Download: Load
10 Restart the drive

Now the follow steps to identify the right motor
  • Make conveyor belt 1 in operating panel
  • After down loading follow these steps:

01 Press Stop button

02 According steps 1 to 5 Up/Download (complete steps 1 to 5 up/down load)

03 Press up arrow button until u gets the parameter 148    Display: 0 0148000 flashing

04 Press right arrow button               Display: 0 flashing 0148000

05 Press up arrow button                  Display: 1 flashing 0148000

06 Press Enter button

07 Start the belt from the DCP-2 panel

08 Press Run button                           Display: The Imp Symbol goes off for ~ 10sec

09 Restart the drive

10 Steps 1-3 again but go to parameter 015 and change from 50 to 87Hz by pressing right
      arrow

11 Restart again

Programming Lenze Drive 9300 Series Main, Aux and Pick Up G2G3G4 by Laptop

TO TAKE BACKUP FROM LENZE DRIVE TO LAPTOP
1Connect LECOM to drive and RS232 cable to Laptop
2Connect 24 Vdc supply to connector no. 39(-) and 59(+)
3Open GDC ( Global Drive Controller) software from desktop
4It starts searching, 'IF not' Press F4 and then F2, select search
5Automatically reading parameter from drive
6Short commissioning 93XX window open
7Select code list
8Select Drive parameters and select write all parameters set to "File"
9Type file name e.g. 05ngr1.GDC and check the saving path.
10Press OK
11Select F4 before quit the program GDC
12Please check saved file in saving path positon.
TO TAKE BACKUP OF LENZE DRIVE AT FOLDER A AND B
1Put jumper in 2 and 3 then connect LECOM 
2Follow above 1 to 12 steps
TO TAKE BACKUP FROM LAPTOP TO LENZE DRIVE
1Connect LECOM to drive and RS232 cable to Laptop
2Connect 24 Vdc supply to connector no. 39(-) and 59(+)
3Open GDC ( Global Drive Controller) software from desktop
4It starts searching, 'IF not' Press F4 and then F2, select search
5Automatically reading parameter from drive
6Short commissioning 93XX window open
7Select Drive parameters and select read all parameter set from file
8Read parameter set from file window open, select the file to be load, press OK
9GDC warning window open, Press Yes, Code list display on window
10Select drive parameters and select write all parameter set to drive
11Warning parameter set transfer window open, Press OK
12Transfer variant selection-parameter set to drive window open
Press exchange unit
13Parametersatztransfer window open
14Start writing parameter to drive, after finish
15Press F4
16Close GDC
17OFF/ON the power of drive
UPLOAD AND DOWNLOAD PARAMETER FROM 2 IN 1 PLC TO PC
1Connect 24 VDC supply to connector no. 3(-) and 2(+)
2Connect cable to RS232 and PC
3Choose program PVI
4Transfer pvi file
5Select execute.
6Downloading starts
7Finish successfully