1 | Switch off Main Switch. |
2 | Move the Position Switch 2 - (1 to 0 for stacker 1, 3 & others). |
Move the Position Switch 2 - (2 to 0 for stacker 2, 4). | |
3 | Switch On the Main Switch. |
4 | After Bootup again Switch off the Main Switch. |
5 | Move the Position Switch 2 - (0 to 1 for stacker 1, 3 & others). |
Move the Position Switch 2 - (0 to 2 for stacker 2, 4). | |
6 | Switch On the Main Switch. |
7 | PLC now Reseted. |